| Technical Specialty |
| Space Frame Systems |
|
| System Details |
|
| |
|
|
 |
| |
| Protection Against Corresion |
|
Space Frame elements protection against corresion can be arranged by ;
1. Galvanizing • Hot Dipped Galvanizing • Electrogalvanizing 2. Paint • Electrostatic Powder Paint • Wet Paint
Tubes ,purlins and purlin stools are first cleaned in acid tanks to remove rust away and than shall receive electrostatic polyester powder coating of avarage 70-80 microns and shall be baked in oven at 200 ¬?C .
If required tubes and purlins can be hot dipped galvanized in conformance with EN 1179 prior to powder coating.
Nodes ,Bolts and Supports shall be electro plated with avarage 25 micron zinc in conformance with ISO 20081.
Slleves shall be hot dipped galvanized in conformance with EN 1179 |
| |
|
| |
|